Onze excuses, wij kunnen u niet aanmelden.
Controleer uw e-mailadres en wachtwoord.
Uw laatste winkelwagen is nog beschikbaar
The basket of your last visit to Black Box is still available.
Wilt u de producten in deze winkelwagen bekijken?
The Black Box website uses cookies. By continuing the use of the Black Box website, or by pressing the agree button on the right, you consent to the use of cookies on this website.
Meer informatie.
ACR (Minimum at 100-m) — 16.3 dB at 100 MHz; 1.4 dB at 200 MHz Attenuation (Minimum at 100-m) — 22.0 dB at 100 MHz; 32.4 dB at 200 MHz; 41.0 dB at 300 MHz; 44.9 dB at 350 MHz Cable Type — 4-pair UTP, 300 V Capacitance Unbalance (Maximum) — 330 pF/100-m (pair to ground) Characteristic Impedance — 1-350 MHz: 100 +/- 15 ohms Conductor — 24 AWG, solid, bare copper Conductor Resistance (Maximum) — 93.8 ohm/20° C (68° F) maximum Delay Skew (Maximum) — 1-350 MHz: 40 nS/100-m EL-FEXT (Minimum at 100-m) — 23.8 dB at 100 MHz; 17.7 dB at 200 MHz; 14.2 dB at 300 MHz; 12.9 dB at 350 MHz NEXT (Minimum at 100-m) — 38.3 dB at 100 MHz; 33.8 dB at 200 MHz; 31.2 dB at 300 MHz; 30.1 dB at 350 MHz PS-ACR (Minimum at 100-m) — PVC: 20.8 dB at 100 MHz; 14.7 dB at 200 MHz; 11.2 dB at 300 MHz; 9.9 dB at 350 MHz PS-ELFEXT (Minimum at 100-m) — 20.8 dB at 100 MHz; 14.7 dB at 200 MHz; 11.2 dB at 300 MHz; 9.9 dB at 350 MHz PS-NEXT (Minimum at 100-m) — 36.3 dB at 100 MHz; 31.8 dB at 200 MHz; 29.2 dB at 300 MHz; 28.1 dB at 350 MHz Return Loss — 20.1 dB at 100 MHz Spark Test — 2.5 KV Velocity Of Propagation (Minimum) — 62.1% at 350 MHz