Foto kan afwijken van werkelijk product
|
|
|
|
|
|
Accessoires
ICD107A: Industrial RS-422/RS-485 DIN Rail Repeater
- Features optical isolation plus 600 W of surge suppression.
- Adds 1219.2 metres and another 32 nodes to an RS-485 data circuit. Configure one side as RS-422 and the other side as RS-485 to enable a 4-wire RS-422 device to communicate with a 2-wire RS-485 device.
- Modbus ASCII or RTU compatible.
- Automatic Send Data Control eliminates the need for driver software.
MED101A: Industrial DIN Rail RS-232/V.24/RS-422/RS-485 <-> Multimode Fibre Driver
- Enables any two async serial devices to communicate half- or full-duplex over two multimode ST fibres at distances up to 4 kilometres.
- RS-232/V.24 signals are supported up to 115.2 kbps; RS-422 or RS-485 signals are supported up to 460.8 kbps.
- Can do fibre ring/RS-485 Multidrop.
- Modbus ASCII or RTU compatible.
- Automatic Send Data Control eliminates the need for driver software.
- Removeable terminal blocks.
MED102A: Industrial DIN Rail RS-232/V.24/RS-422/RS-485 <-> Single Mode Fibre Driver
- Provides connections between asychronous full- or half duplex serial equipment over duplex single-mode fibre.
- Extends communications up to 15 km.
- Supports serial data up to 115.2 Kbps.
- Can do fibre ring/RS-485 Multidrop.
- Modbus ASCII or RTU compatible.
- Automatic Send Data Control eliminates the need for driver software.
- Removeable terminal blocks.
Distance (Maximum) —
ICD107A: 1.2km
MED101A: 4km
MED102A: 14.4km
Operating Environment —
Temperature: -40 to +85°C;
Humidity: Up to 95% non-condensing
Operation —
ICD107A:
RS-422: Full-duplex;
RS-485: 2-wire half-duplex or 4-wire full-duplex
MED101A:
RS-232/V.24: Half- or full-duplex;
RS-422: Full-duplex;
RS-485: 2-wire half-duplex or 4-wire full-duplex;
Fibre ring: Half-duplex over multimode;
All transmissions are async
MED102A:
RS-232/V.24: Half- or full-duplex;
RS-422/: 2-wire half-duplex or 4-wire full-duplex;
Fibre ring: Half-duplex over singlemode;
All transmissions are async
Speed —
ICD107A: 2400 bps to 115.2 kbps, switch-selectable; other rates available up to 460.8 kbps
MED101A/MED102A: RS-232/V.24: Up to 115.2 kbps; RS-422/RS-485: Up to 460.8 kbps
Bus Compatibility— MED102A: MODBUS ASCII or RTU
Isolation— MED102A: 2 KV RMS for 1 Minute 3 Way
Connectors —
ICD107A: (2) 5-position terminal blocks
MED101A: (2) 5-position terminal blocks, (1) pair of Multimode ST
MED102A: (1) 2-position terminal block, (1) 5-position terminal block, (1) duplex single-mode SC
Power — +10 to 48VDC (+/- 20%) or from optional DIN Rail 12VDC Power Supply (PSD100)
Dimensions —
ICD107A: 9.9(H) x 7.4(W) x 2.3(D) cm
MED101A: 12.4(H) x 11.4(W) x 3.3(D) cm
MED102A: 8.9(H) x 3(W) x 12.8(D) cm
|